Confidently measure pressure and level with the Rosemount 3051 In-Line Pressure Transmitter. Engineered for 10-year installed stability and 0.04% of span accuracy, this industry-leading pressure transmitter provides you with the information necessary to run, control and monitor processes. Available with a graphical, back-lit display, Bluetooth® connectivity, and enhanced software capabilities designed to access the data you need faster than ever before.

Description

Features

In-line gage and absolute pressure measurements support up to 20,000 psi (1378,95 bar) for pressure or level solutions

Application specific configuration allows you to transform your pressure transmitter into a level transmitter with volume calculations

Complete pressure or level assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation

10-year installed stability and 150:1 rangedown produce reliable measurements and wide application flexibility

Bluetooth® wireless connectivity unlocks a far simpler process to perform maintenance and service tasks without the need for a physical connection or separate configuration tool

The graphical, back-lit display allows for easy operation in 8 different languages in all lighting conditions

Loop Integrity and Plugged Impulse Line diagnostics detect electrical loop issues and plugged impulse piping before it impacts the quality of the process for increased safety and reduced downtime

Quick service buttons offer built-in configuration buttons for streamlined commissioning

SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

Wireless Features

WirelessHART® technology is secure and cost-effective and delivers >99% data reliability

SmartPower™ module provides up to 10-year maintenance-free operation and field replacement without transmitter removal

Easy installation enables quick instrumentation of measurement points without the cost of wiring

 

Specifications

Warranty            Up to 5-year limited warranty
Rangedown            Up to 150:1
Communication Protocol    4-20 MA HART®, WirelessHART®, FOUNDATION™ fieldbus, PROFIBUS® PA, 1-5 V Low Power HART®
Measurement Range       Up to 20000 psig (1378,95 bar) gage
                  Up to 20000 psia (1378,95 bar) absolute
Process Wetted Material   316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated 316L SST, Gold-plated Alloy 400
Diagnostics           Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics
Certifications/Approvals  SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE®, hazardous location, see full specs for complete list of certifications
Wireless Update Rate     1 sec. to 60 min., user selectable
Power Module Life       Up to 10-year life, field replaceable (order separately)
Wireless Range         Internal antenna (225 m)
 
Order Code:
 

Code

Description

3051T

In-Line Pressure Transmitter

Pressure type

Code

Description

 

G

Gage

A(1)

Absolute

Pressure range

Code

Gage (Rosemount 3051TG)(1)

Absolute (Rosemount 3051TA)

 

0

–5 to 5 psi (-344.74 to 344.74 mbar)

N/A

1

–14.7 to 30 psi (-1.01 to 2.06 bar)

0 to 30 psia (0 to 2.06 bar)

2

–14.7 to 150 psi (-1.01 to 10.34 bar)

0 to 150 psia (0 to 10.34 bar)

3

–14.7 to 800 psi (-1.01 to 55.15 bar)

0 to 800 psia (0 to 55.15 bar)

4

–14.7 to 4000 psi (-1.01 to 275.79 bar)

0 to 4000 psia (0 to 275.79 bar)

5

–14.7 to 10000 psi (-1.01 to 689.47 bar)

0 to 10000 psia (0 to 689.47 bar)

6(2)

–14.7 to 20000 psi (–1.01 to 1378.95 bar)

0 to 20000 psia (0 to 1378.95 bar)

 

Transmitter output

Code

Description

 

A(1)

4–20 mA with digital signal based on HART® Protocol

F

FOUNDATION™ Fieldbus Protocol

W(2)

PROFIBUS® PA Protocol

X(3)

Wireless (requires wireless options and engineered polymer housing)

M(4)

Low-power, 1–5 Vdc with digital signal based on HART Protocol

 

Process connection style

Code

Description

 

2B

½-14 NPT female (range 1-5 only)

2C(1)

G½ A EN837-1 male (range 1-4 only)

2F(2)

Coned and threaded, compatible with autoclave Type F-250-C (range 5-6 only)

 

61(3)(4)

Non-threaded instrument flange (range 1-4 only)

 

Isolating diaphragm

Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Code

Isolating diaphragm

Process connection wetted parts material

 

2

316L stainless steel

316L stainless steel

3

Alloy C-276

Alloy C-276

7

Gold-plated 316 stainless steel

316L stainless steel

 

Sensor fill fluid

Code

Description

 

1

Silicone

2(1)

Inert

 

(1) Not available with wireless output.

 

 

Housing material

Code

Housing material

Conduit entry size

 

A

Aluminum

½-14 NPT

B

Aluminum

M20 x 1.5

E

Aluminum, ultra low copper

½-14 NPT

 

F

Aluminum, ultra low copper

M20 x 1.5

 

J

Stainless steel

½-14 NPT

K

Stainless steel

M20 x 1.5

 

P(1)

Engineered polymer

No conduit entries

D(2)

Aluminum

 

M(2)

Stainless steel

 

Wireless options

Requires wireless output code X and engineered polymer housing code P.

Wireless transmit rate, operating frequency, and protocol

Code

Description

 

WA3

User configurable transmit rate, 2.4 GHz WirelessHART®

Antenna and SmartPower

Code

Description

 

WP5

Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately).

Additional options

Extended product warranty

Code

Description

 

WR3

3-year limited warranty

WR5

5-year limited warranty

Plantweb™ control functionality

Code

Description

 

A01

FOUNDATION™ Fieldbus control function block suite

Plantweb™ diagnostic functionality

Code

Description

 

DA0

Loop Integrity HART® Diagnostic

D01

FOUNDATION™ Fieldbus Diagnostics Suite

Integral assembly

"Assemble-to" items are specified separately and require a completed model number.

Code

Description

 

S5

Assemble to Rosemount 306 Integral Manifold

 

Diaphragm seal assemblies

"Assemble-to" items are specified separately and require a completed model number.

Code

Description

 

S1

Assemble to one Rosemount 1199 seal

Mounting bracket

Panel mounting bolts are not supplied.

Code

Description

 

B4

Bracket for 2-in. pipe or panel mounting, all stainless steel

Product certifications

Code

Description

 

E8

ATEX Flameproof and Dust Certification

I1(1)

ATEX Intrinsic Safety and Dust

IA

ATEX FISCO Intrinsic Safety; for FOUNDATION™ Fieldbus or PROFIBUS® PA Protocol only

N1

ATEX Type n Certification and Dust

K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)

E4

TIIS Flame-proof

I4

TIIS Intrinsic Safety

E5

USA Explosion-proof, Dust Ignition-Proof

I5(2)

USA Intrinsically Safe, Nonincendive

C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2

E6

Canada Explosion-proof, Dust Ignition-proof, Division 2

I6

Canada Intrinsic Safety

K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)

E7

IECEx Flameproof, Dust Ignition-proof

I7

IECEx Intrinsic Safety

N7

IECEx Type n Certification

K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)

IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2

E2

INMETRO Flameproof001

I2

INMETRO Intrinsic Safety

IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

K2

INMETRO Flameproof, Intrinsic Safety

E3

China Flameproof

I3

China Intrinsic Safety

 

N3

China Type n

EM

Technical Regulations Customs Union (EAC) Flameproof

IM

Technical Regulations Customs Union (EAC) Intrinsic Safety

KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety

KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)

KL(3)

USA, Canada, IECEx, ATEX Intrinsic Safety Combination

KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2

EP

Republic of Korea Flameproof

IP

Republic of Korea Intrinsic Safety

KP

Republic of Korea Flameproof, Intrinsic Safety

Dust approval not applicable to output code X.

Nonincendive certification not provided with output code (X).

Only available with output code X.

 

 

Drinking water approval

Not available with alloy isolator (option code 3), assemble-to manifolds (option code S5), assemble-to seals (option code S1), surface finish certification (option code Q16), and remote seal system report (option code QZ).

Code

Description

 

DW

NSF drinking water approval

Shipboard approvals

Shipyard approvals are not available with wireless output (code X).

Code

Description

 

SBS

American Bureau of Shipping

SBV(1)

Bureau Veritas (BV)

SDN

Det Norske Veritas

SLL(1)

Lloyds Register (LR)

(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7

 

 

SST tagging

Code

Description

 

Y2

316 SST nameplate, top tag, wire-on tag, and fasteners

 

Custody transfer

The custody transfer option is only available with HART 4–20 mA output (code A).

 

Code

Description

 

C5

Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an Emerson representative).

Calibration certification

Code

Description

 

Q4

Calibration certificate

QG

Calibration certificate and GOST verification certificate

QP

Calibration certificate and tamper evident seal

Material traceability certification

Code

Description

 

Q8

Material traceability certification per EN 10204 3.1.B

Positive material identification (PMI)

Code

Description

Q76

PMI verification and certificate

Quality certification for safety

The quality certification for safety is only available with HART® 4–20 mA output (code A).

Code

Description

 

QT

Safety certified to IEC 61508 with certificate of FMEDA

Configuration buttons

Code

Description

 

D4(1)

Analog zero and span

DZ(2)

Digital zero trim

Only available with HART 4–20 mA output (code A).

Only available with HART 4–20 mA output (output code A) and wireless output (output code X).

 

 

Display and interface options

Code

Description

 

M4(1)

LCD display with LOI

M5

LCD display

(1) Only available with 4-20 mA HART output (code A) and PROFIBUS-PA (code W).

 

 

Wireless sensor module

Code

Description

 

WSM

Wireless stainless steel sensor module

Transient protection

The transient protection option is not available with wireless output (code X). The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.

Code

Description

 

T1

Transient protection terminal block

Conduit plug

The conduit plug option is not available with wireless output (code X).

Code

Description

 

DO

316 SST conduit plug

Software configuration

Code

Description

 

C1

Custom software configuration. (Completed Rosemount 3051 Wireless Configuration Data Sheet required with order.)

Low power output

Code

Description

 

C2

0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)

Alarm levels

The alarm levels option is only available with HART 4–20 mA output (code A).

Code

Description

 

C4(1)

Analog output levels compliant with NAMUR recommendation NE 43, alarm high

CN(1)

Analog output levels compliant with NAMUR recommendation NE 43, alarm low

CR

Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)

CS

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)

CT

Rosemount standard low alarm

(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

 

 

Pressure testing

Code

Description

 

P1(1)

Hydrostatic testing with certificate

(1) Not available with pressure range 0.

 

 

Cleaning process area

Not valid with alternate process connection S5.

Code

Description

P2

Cleaning for special service

P3

Cleaning for < 1 ppm chlorine/fluoride

Ground screw

The ground screw option is not available with wireless output (code X). The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code

Description

 

V5

External ground screw assembly

High accuracy

Only available with standard Rosemount 3051. See Specifications section for more information.

Code

Description

 

P8

0.04% accuracy to 5:1 turndown (range 2-4)

Surface finish

Code

Description

 

Q16

Surface finish certification for sanitary remote seals

Toolkit total system performance reports

Code

Description

 

QZ

Remote seal system performance calculation report

Conduit electrical connector

The conduit electrical connector option is not available with wireless output (code X).

Code

Description

 

GE

M12, 4-pin, male connector (eurofast®)

GM

A size mini, 4-pin, male connector (minifast®)

NACE certificate

Note that NACE®-compliant wetted materials are required. Materials of construction must comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult the latest standard for details. All selected materials must also conform to NACE MR0103 for sour refining environments.

Code

Description

 

Q15

Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials

Q25

Certificate of Compliance to NACE MR0103 for wetted materials

Cold temperature

This option is only available for pressure type D and G, pressure ranges 1–5 with 4-20 mA HART® protocol, and silicone sensor fill fluid. It is available with 316SST, C-276, gold plated SST isolating diaphragms, and with transmitter flange types 2, 7, and 0 (only for HJ, HK, and HL). BR5 and BR6 are not available with the following options: DC, DF, D7, D9, P9, Q16, GE, and GM. Consult factory for available approvals.

Code

Description

 

BR5(1)

–58 °F (–50 °C) cold temperature operation

BR6(2)

–76 °F (–60 °C) cold temperature operation

BR5 option is only available with approval codes C6, E2, E5, EM, I2, I5, I7, IM, IP, K5, KM, and KP.

BR6 option is only available with approval codes EM, I2, I7, IM, IP, and KM.

 

 

HART revision configuration (requires HART Protocol output code A)

HART® Revision 5 is the default HART output.

Code

Description

 

HR5

Configured for HART Revision 5

HR7

Configured for HART Revision 7

Wireless power accessory

This option is only available with output code X.

Code

Description

 

HS

Hot swap power adapter for power module replacement

 

 