+86-535-4284215

Rosemount™ 3051L Level Transmitter

Features

Power advisory diagnostics proactively monitor electrical loop integrity

Local Operator Interface (LOI) for simple, local commissioning on-site without the use of extra tools

Tuned-System Level assembly and direct mounting produce optimal performance for level applications

Factory-assembled and out-of-the-box ready level solution eliminates on-site assembly, testing and calibration

Optimized seal system construction ensures a quality measurement in harsh process conditions

SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

 

Tech Parameters

Warranty           Up to 5-year limited warranty
 
Max. Operating Pressure Up to 300 psi (20,68 bar)
 
Process Temperature Range
Based on fill fluid:   Maximum 401°F (205°C), Minimum -157°F (-105°C)
 
Communication Protocol 4-20 MA HART®, WirelessHART®, FOUNDATION™ fieldbus, PROFIBUS® PA, 1-5 V Low Power HART®
 
Seal System Type     Direct Mount, Tuned-System
 
Transmitter Connection Welded-Repairable
 
Process Connection   Flanged: ANSI/ASME, EN/DIN, JIS
 
Process Wetted Material 316L SST, Alloy C-276, Tantalum
 
Diagnostics         Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics
 
Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications
 
Wireless Update Rate  1 sec. to 60 min., user selectable
 
Power Module Life    Up to 10-year life, field replaceable (order separately)
 
Wireless Range      Internal antenna (225 m)
 

Model

Code

Description

 

3051L

Level transmitter

Pressure range

Code

Description

 

2

–250 to 250 inH2O (–621.60 to 621.60 mbar)

3

–1000 to 1000 inH2O (–2.48 to 2.48 bar)

4

–300 to 300 psi (–20.68 to 20.68 bar)

Transmitter output

Code

Description

 

A(1)

4–20 mA with digital signal based on HART® Protocol

F

FOUNDATION™ Fieldbus Protocol

W(2)

PROFIBUS® PA Protocol

X(3)

Wireless (requires wireless options and engineered polymer housing)

M(4)

Low-power, 1–5 Vdc with digital signal based on HART Protocol

 

HART Revision 5 is the default HART output.

For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS, N3.

This option is only available with intrinsically safe approvals.

Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

 

 

Process connection size, material, extension length (high side)

Code

Process connection size

Material

Extension length

 

G0(1)

2-in./DN 50/A

316L SST

Flush mount only

H0(1)

2-in./DN 50

Alloy C-276

Flush mount only

J0

2-in./DN 50

Tantalum

Flush mount only

A0(1)

3-in./DN 80

316L SST

Flush mount

A2(1)

3-in./DN 80

316L SST

2-in./50 mm

A4(1)

3-in./DN 80

316L SST

4-in./100 mm

A6(1)

3-in./DN 80

316L SST

6-in./150 mm

B0(1)

4-in./DN 100

316L SST

Flush mount

B2(1)

4-in./DN 100

316L SST

2-in./50 mm

B4(1)

4-in./DN 100

316L SST

4-in./100 mm

B6(1)

4-in./DN 100

316L SST

6-in./150 mm

C0(1)

3-in./DN 80

Alloy C-276

Flush mount

C2(1)

3-in./DN 80

Alloy C-276

2-in./50 mm

C4(1)

3-in./DN 80

Alloy C-276

4-in./100 mm

C6(1)

3-in./DN 80

Alloy C-276

6-in./150 mm

D0(1)

4-in./DN 100

Alloy C-276

Flush mount

D2(1)

4-in./DN 100

Alloy C-276

2-in./50 mm

D4(1)

4-in./DN 100

Alloy C-276

4-in./100 mm

D6(1)

4-in./DN 100

Alloy C-276

6-in./150 mm

E0

3-in./DN 80

Tantalum

Flush mount only

F0

4-in./DN 100

Tantalum

Flush mount only

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

 

 

Mounting flange size, rating, material (high side)

Code

Size

Rating

Material

 

M

2-in.

ASME B16.5 Class 150

CS

A

3-in.

CS

B

4-in.

CS

N

2-in.

ASME B16.5 Class 300

CS

C

3.in.

CS

D

4-in.

CS

P

2-in.

ASME B16.5 Class 600

CS

E

3-in.

CS

X(1)

2-in.

ASME B16.5 Class 150

316 SST

F(1)

3-in.

316 SST

G(1)

4-in.

316 SST

Y(1)

2-in.

ASME B16.5 Class 300

316 SST

H(1)

3-in.

316 SST

J(1)

4-in.

316 SST

Z(1)

2-in.

ASME B16.5 Class 600

316 SST

L(1)

3-in.

316 SST

Q

DN 50

PN 10-40 per EN 1092-1

CS

R

DN 80

PN 40 per EN 1092-1

CS

S

DN 100

CS

V

DN 100

PN 10/16 per EN 1092-1

CS

K(1)

DN 50

PN 10-40 per EN 1092-1

316 SST

T(1)

DN 80

PN 40 per EN 1092-1

316 SST

U(1)

DN 100

316 SST

W(1)

DN 100

PN 10/16 per EN 1092-1

316 SST

7(1)

4-in.

ASME B16.5 Class 600

316 SST

1

N/A

10K per JIS B2238

316 SST

 

2

N/A

20K per JIS B2238

CS

 

3

N/A

40K per JIS B2238

CS

 

4(1)

N/A

10K per JIS B2238

CS

 

5(1)

N/A

20K per JIS B2238

316 SST

 

6(1)

N/A

40K per JIS B2238

316 SST

 

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

 

 

Seal fill fluid

Code

Description

Specific gravity

Temperature limits (ambient temperature of 70° F [21° C])

 

D

Silicone 200

0.93

–49 to 401 °F (–45 to 205 °C)

F

Silicone 200 for vacuum applications

0.93

For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.

L

Dow Corning® 704 diffusion pump fluid

1.07

32 to 401 °F (0 to 205 °C)

C

D.C. Silicone 704 for vacuum applications

1.07

For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.

A

SYLTHERM™ XLT

0.85

–102 to 293 °F (–75 to 145 °C)

H

Inert (halocarbon)

1.85

–49 to 320 °F (–45 to 160 °C)

G

Glycerin and water

1.13

5 to 203 °F (–15 to 95 °C)

N

Neobee® M-20

0.92

5 to 401 °F (–15 to 205 °C)

P

Propylene glycol and water

1.02

5 to 203 °F (–15 to 95 °C)

Low pressure side

Code

Configuration

Flange adapter

Diaphragm material

Sensor fluid

 

11(1)

Gage

SST

316L SST

Silicone

21

Differential

SST

316 SST

Silicone

22(1)

Differential

SST

Alloy C-276

Silicone

2A(2)

Differential

SST

316 SST

Inert (halocarbon)

2B(1)(2)

Differential

SST

Alloy C-276

Inert (halocarbon)

31(1)

Tuned-system assembly with remote seal

None

316 SST

Silicone (requires option code S1)

Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Not available with wireless output code X.

 

 

O-ring

Code

Description

 

A

Glass-filled PTFE

Housing material

Code

Material

Conduit entry size

 

A

Aluminum

½–14 NPT

B

Aluminum

M20 x 1.5

 

Code

Material

Conduit entry size

 

E

Aluminum, ultra low copper

½–14 NPT

 

F

Aluminum, ultra low copper

M20 x 1.5

 

J

SST

½–14 NPT

K

SST

M20 x 1.5

P(1)

Engineered polymer

No conduit entries

D(2)

Aluminum

 

M(2)

SST

 

Only available with wireless output code X.

Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. Only available with product certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG

 

 

 

Wireless options

Requires wireless output code X and Engineered Polymer Housing code P.

Wireless transmit rate, operating frequency, and protocol

Code

Description

 

WA3

User configurable transmit rate, 2.4 GHz WirelessHART

Antenna and SmartPower

Code

Description

 

WP5

Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)

Addtional options

Include with selected model number.

Extended product warranty

Code

Description

 

WR3

3-year limited warranty

WR5

5-year limited warranty

Plantweb™ control functionality

Code

Description

 

A01

FOUNDATION™ Fieldbus control function block suite

 

Plantweb™ diagnostic functionality

Code

Description

 

DA0

Loop Integrity HART® Diagnostic

D01

FOUNDATION™ Fieldbus Diagnostics Suite

Seal assemblies

“Assemble-to” items are specified separately and require a completed model number.

Code

Description

 

S1

Assembled to one Rosemount 1199 Seal

Remote seal diaphragm coating

Code

Description

SZ

0.0002-in. (5 µm) gold-plated diaphragm

 

FP(1)

CorrosionShield PFA coated diaphragm

 

(1) Not compatible with spiral wound gasket.

 

 

Product certifications

Code

Description

 

E8

ATEX Flameproof and Dust Certification

I1(1)

ATEX Intrinsic Safety and Dust

IA

ATEX FISCO Intrinsic Safety; for FOUNDATION™ Fieldbus or PROFIBUS® PA Protocol only

N1

ATEX Type n Certification and Dust

K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)

E4

TIIS Flame-proof

I4

TIIS Intrinsic Safety

E5

USA Explosion-proof, Dust Ignition-Proof

I5(2)

USA Intrinsically Safe, Nonincendive

C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2

E6

Canada Explosion-proof, Dust Ignition-proof, Division 2

I6

Canada Intrinsic Safety

K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)

E7

IECEx Flameproof, Dust Ignition-proof

I7

IECEx Intrinsic Safety

N7

IECEx Type n Certification

K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)

IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

 

K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2

E2

INMETRO Flameproof001

I2

INMETRO Intrinsic Safety

IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

K2

INMETRO Flameproof, Intrinsic Safety

E3

China Flameproof

I3

China Intrinsic Safety

N3

China Type n

EM

Technical Regulations Customs Union (EAC) Flameproof

IM

Technical Regulations Customs Union (EAC) Intrinsic Safety

KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety

KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)

KL(3)

USA, Canada, IECEx, ATEX Intrinsic Safety Combination

KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2

EP

Republic of Korea Flameproof

IP

Republic of Korea Intrinsic Safety

KP

Republic of Korea Flameproof, Intrinsic Safety

Dust approval not applicable to output code X.

Nonincendive certification not provided with output code (X).

Only available with output code X.

 

 

Shipboard approvals

Shipyard approvals are not available with wireless output (code X).

Code

Description

 

SBS

American Bureau of Shipping

SBV(1)

Bureau Veritas (BV)

SDN

Det Norske Veritas

SLL(1)

Lloyds Register (LR)

(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7

 

 

SST tagging

Code

Description

 

Y2

316 SST nameplate, top tag, wire-on tag, and fasteners

 
 

Bolting material

Code

Description

 

L4

Austenitic 316 SST bolts

Display and interface options

Code

Description

 

M4(1)

LCD display with LOI

M5

LCD display

(1) Only available with 4-20 mA HART® output (code A) and PROFIBUS®-PA (code W).

 

 

Calibration certificate

Code

Description

 

Q4

Calibration certificate

QG(1)

Calibration certificate and GOST verification certificate

QP

Calibration certification and tamper evident seal

(1) Contact an Emerson representative for availability.

 

 

Material traceability certification

Code

Description

 

Q8

Material traceability certification per EN 10204 3.1

Positive material identification (PMI)

Code

Description

Q76

PMI verification and certificate

Quality certification for safety

The quality certification for safety is only available with HART® 4–20 mA output (code A).

Code

Description

 

QT

Safety certified to IEC 61508 with certificate of FMEDA

Toolkit total system performance reports

Code

Description

 

QZ

Remote seal system performance calculation report

Conduit electrical connector

The conduit electrical connector option is not available with wireless output (code X).

 

Code

Description

 

GE

M12, 4-pin, male connector (eurofast®)

GM

A size mini, 4-pin, male connector (minifast®)

Configuration buttons

Code

Description

 

D4(1)

Analog zero and span

DZ(2)

Digital zero trim

Only available with HART® 4–20 mA output (code A).

Only available with HART 4–20 mA output (output code A) and wireless output (output code X)

 

 

Transient protection

The transient protection option is not available with wireless output (code X). The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.

Code

Description

 

T1

Transient protection terminal block

Software configuration

The software configuration option is only available with HART® 4–20 mA output (output code A) and wireless output (output code X).

Code

Description

 

C1

Custom software configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)

Low power output

Code

Description

 

C2

0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)

Alarm levels

The alarm levels option is only available with HART 4–20 mA output (code A).

Code

Description

 

C4(1)

Analog output levels compliant with NAMUR recommendation NE 43, alarm high

CN(1)

Analog output levels compliant with NAMUR recommendation NE 43, alarm low

CR

Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)

CS

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)

CT

Rosemount standard low alarm

(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

 

 

Conduit plug

The conduit plug option is not available with wireless output (code X).

Code

Description

 

DO

316 SST conduit plug

Ground screw

The ground screw option is not available with wireless output (code X). The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code

Description

 

V5

External ground screw assembly

Lower housing flushing connection options

Code

Ring material

Number

Size (NPT)

 

F1

316 SST

1

¼–18 NPT

F2

316 SST

2

¼–18 NPT

F3

Alloy C-276

1

¼–18 NPT

F4

Alloy C-276

2

¼–18 NPT

F7

316 SST

1

½–14 NPT

F8

316 SST

2

½–14 NPT

F9

Alloy C-276

1

½–14 NPT

F0

Alloy C-276

2

½–14 NPT

Lower housing intermediate gasket material

Code

Description

 

S0

No gasket for lower housing

SY(1)

Thermo-Tork® TN-9000

(1) Gasket provided when lower housing is ordered.

 

 

NACE certificate

Note that NACE®-compliant wetted materials are required. Materials of construction must comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult the latest standard for details. All selected materials must also conform to NACE MR0103 for sour refining environments.

Code

Description

 

Q15

Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials

Q25

Certificate of Compliance to NACE MR0103 for wetted materials

HART revision configuration (requires HART Protocol output code A)

HART® Revision 5 is the default HART output.

 

Code

Description

 

HR5

Configured for HART Revision 5

HR7

Configured for HART Revision 7

Wireless power accessory

This option is only available with output code X.

Code

Description

 

HS

Hot swap power adapter for power module replacement

 

 
 

As one of the most professional rosemount™ 3051l level transmitter manufacturers and suppliers in China, we're featured by quality products and low price. Please rest assured to buy customized rosemount™ 3051l level transmitter from our factory. Contact us for pricelist and quotation.

Fork Type Concentration Transmitter, Oval Gear Flowmeter, Slurry Flowmeter
Contact Supplier