Differential, Gauge or Absolute pressure measurements Elevates safety in the workplace Configurable to fit many applications For use with flanges or Coplanar platform Installed five year stability of 0.125% Range of outputs and hazardous area certificates

Description

SPECIFICATIONS

*±0.04% maximum accuracy

*Coplanar process connection

*Measures up to 4000 psi absolute and 2000 psi gauge and differential

*Pressure measurement with differential, gauge or absolute

*±0.15% "real world" transmitter performance

*Potential Outputs: FOUNDATION Fieldbus, PROFIBUS, 4-20mA with HART protocol, 1-5 VDC with HART protocol

*±0.125% five year stability

 

Model codes

 

Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 1.

 

Figure 1: Model Code Example

 

product-196-59

Model

Code

Description

 

3051C

Coplanar pressure transmitter

Measurement type

Code

Description

 

D

Differential

G

Gage

A(1)

Absolute

 

 

Pressure range

Code

Differential

Gage

Absolute

 

 

(Rosemount 3051CD)

(Rosemount 3051CG)

(Rosemount 3051CA)

 

1

–25 to 25 inH2O

–25 to 25 inH2O

0 to 30 psia

 

(–62.16 to 62.16 mbar)

(–62.16 to 62.16 mbar)

(0 to 2.06 bar)

 

2

–250 to 250 inH2O

–250 to 250 inH2O

0 to 150 psia

 

(–621.60 to 621.60 mbar)

(–621.60 to 621.60 mbar)

(0 to 10.34 bar)

 

3

–1000 to 1000 inH2O

–393 to 1000 inH2O

0 to 800 psia

 

(–2.48 to 2.48 bar)

(–0.97 to 2.48 bar)

(0 to 55.15 bar

 

4

–300 to 300 psi

–14.2 to 300 psi

0 to 4000 psia

 

(–20.68 to 20.68 bar)

(–0.97 to 20.68 bar)

(0 to 275.79 bar)

 

5

–2000 to 2000 psi

–14.2 to 2000 psi

N/A

 

(–137.89 to 137.89 bar)

(–0.97 to 137.89 bar)

 

 

0(1)

–3 to 3 inH2O

N/A

N/A

 

 

(-7.46 to 7.46 mbar)

 

 

 

 

Transmitter output

Code

Description

 

 

 

 

A

4–20 mA with digital signal based on HART® Protocol

F

FOUNDATION Fieldbus Protocol

W

PROFIBUS® PA Protocol

X

Wireless (requires wireless options and engineered polymer housing)

M Low-power, 1–5 Vdc with digital signal based on HART Protocol  

 

Materials of construction

Code

Transmitter flange type

Flange material

Drain/vent

 

2

Coplanar

SST

SST

3(1)

Coplanar

Cast C-276

Alloy C-276

4

Coplanar

Alloy 400

Alloy 400/K-500

5

Coplanar

Plated CS

SST

7(1)

Coplanar

SST

Alloy C-276

8(1)

Coplanar

Plated CS

Alloy C-276

0

Alternate process connection

 

 

Isolating diaphragm

Code

Description

 

 

 

 

2(1)

316L SST

3(1)

Alloy C-276

4(2)

Alloy 400

 

5(2)

Tantalum (available on Rosemount 3051CD and CG, ranges 2–5 only; not available on Rosemount 3051CA)

 

6(2)

Gold-plated alloy 400 (use in combination with O-ring option code B)

 

7(2)

Gold-plated 316 SST

 

 

O-ring

Code

Description

 

A

Glass-filled PTFE

B

Graphite-filled PTFE

 

Sensor fill fluid

Code

Description

 

1

Silicone

2(1)

Inert (differential and gage only)

 

Housing material

Code

Description

Conduit entry size

 

A

Aluminum

½–14 NPT

B

Aluminum

M20 x 1.5

E

Aluminum, ultra low copper

½–14 NPT

F

Aluminum, ultra low copper

M20 x 1.5

J

SST

½–14 NPT

K

SST

M20 x 1.5

P(1)

Engineered polymer

No conduit entries

D(2)

Aluminum

 

M(2)

SST

 

 

Extended product warranty

Code

Description

 

WR3

3-year limited warranty

WR5

5-year limited warranty

 

Alternate flange

Code

Description

 

H2

Traditional flange, 316 SST, SST drain/vent

H3(1)

Traditional flange, alloy C, alloy C-276 drain/vent

H4

Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent

H7(1)

Traditional flange, 316 SST, alloy C-276 drain/vent

HJ

DIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting

FA

Level flange, SST, 2-in. (51 mm), ANSI Class 150, vertical mount 316 SST drain/vent

FB

Level flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent

FC

Level flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent

FD

Level flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent

FP

DIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent

FQ

DIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent

HK(2)

DIN compliant traditional flange, SST, 0.40 in. (10 mm) adapter/manifold bolting 316 SST

 

HL

DIN compliant traditional flange, SST, 0.50 in. (12 mm) adapter/manifold bolting 316 SST

 

 

Manifold assembly

Code

Description

 

 

S5

Assemble to Rosemount 305 Integral Manifold

 

S6

Assemble to Rosemount 304 Manifold or Connection System

 

 

Mounting bracket

Code

Description

 

B4

Coplanar flange bracket, all SST, 2-in. (51 mm) pipe and panel

B1

Traditional flange bracket, CS, 2-in. (51 mm) pipe

B2

Traditional flange bracket, CS, panel

B3

Traditional flange flat bracket, CS, 2-in. (51 mm) pipe

B7

Traditional flange bracket, B1 with SST bolts

B8

Traditional flange bracket, B2 with SST bolts

B9

Traditional flange bracket, B3 with SST bolts

BA

Traditional flange bracket, B1, all SST

BC

Traditional flange bracket, B3, all SST

 

Product certifications

Code

Description

 

E8

ATEX Flameproof and Dust Certification

I1(1)

ATEX Intrinsic Safety and Dust

 

IA

ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS® PA Protocol only

 

N1

ATEX Type n Certification and Dust

 

 

 

 

 

K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)

 

 

 

 

 

E4

TIIS Flame-proof

 

 

 

 

 

I4

TIIS Intrinsic Safety

 

 

 

 

 

E5

USA Explosion-proof, Dust Ignition-Proof

 

 

 

 

 

I5(2)

USA Intrinsically Safe, Nonincendive

 

C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2

 

 

 

 

 

E6

Canada Explosion-proof, Dust Ignition-proof, Division 2

 

 

 

 

 

I6

Canada Intrinsic Safety

 

 

 

 

 

K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)

 

 

 

 

 

E7

IECEx Flameproof, Dust Ignition-proof

 

 

 

 

 

I7

IECEx Intrinsic Safety

 

 

 

 

 

N7

IECEx Type n Certification

 

 

 

 

 

K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)

 

 

 

 

 

IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

 

 

 

 

 

K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2

 

 

 

 

 

E2

INMETRO Flameproof001

 

 

 

 

 

I2

INMETRO Intrinsic Safety

 

 

 

 

 

IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only

 

 

 

 

 

K2

INMETRO Flameproof, Intrinsic Safety

 

 

 

 

 

E3

China Flameproof

 

 

 

 

 

I3

China Intrinsic Safety

 

 

 

 

 

N3

China Type n

 

 

 

 

 

EM

Technical Regulations Customs Union (EAC) Flameproof

 

 

 

 

 

IM

Technical Regulations Customs Union (EAC) Intrinsic Safety

 

 

 

 

 

KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety

 

 

 

 

KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)

 

 

 

 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)

 

 

 

 

 

KL(3)

USA, Canada, IECEx, ATEX Intrinsic Safety Combination

 

KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2

 

 

 

 

 

EP

Republic of Korea Flameproof

 

 

 

 

 

IP

Republic of Korea Intrinsic Safety

 

 

 

 

 

KP

Republic of Korea Flameproof, Intrinsic Safety

 

 

 

 

 

 

 

 

Hot Tags: rosemount 3051c smart pressure transmitter, China rosemount 3051c smart pressure transmitter manufacturers, suppliers

Contact Supplier