GENERAL
4-20ma Double Flange Differential Pressure Transmitter For Liquid Gas is a digital differential pressure transmitter designed for industrial pressure measurement applications. It can be configured to provide integrated solutions for a broad range of pressure and flow measurement applications.
FEATURES
►Updating time of output current in 200 ms
►Improved performance, increased accuracy and greater stability
►Two years stability of 0.2%
►0.075% accuracy
►Parameter setting by keypad directly
►4-20 mA output plus direct digital HART communication
►Automatic zero calibration by press-button
►Explosion proof and weather proof housing
SPECIFICATIONS
|
Process Fluid |
Liquid, Gas , Vapor |
|
Application |
Absolute Pressure, Gauge Pressure, Differential Pressure |
|
Measuring Range |
0 - 0.16 kPa ~ 0 - 1.0 kPa (Min) 0 - 4.0 MPa ~ 0 - 20.0 MPa (Max) |
|
Accuracy |
+/- 0.05% of span |
|
Stability |
+/-0.10% of URL for 2 years |
|
Working Temperature |
-25 to +30 °C |
|
Max. Pressure |
35 MPa |
|
Material |
Flange : Stainless Steel 304 / 316 |
|
Drains/Vents : Stainless Steel 304 / 316 |
|
|
Diaphragm : Stainless Steel 316L / Hastelloy B / Hastelloy C / Monel / Tantalum |
|
|
Wetted O-Ring |
Buna N / Viton / PTFE |
|
Bolts & Nuts |
Carbon Steel / Stainless Steel 316 |
|
Mounting Bracket |
Carbon steel / Stainless Steel 304 / 316 |
|
Name / Tag Plate |
Stainless Steel 304 / Stainless Steel 316 |
|
Converter Housing |
Low copper cast aluminum alloy with polyurethane, light blue paint |
|
Fill Fluid |
Silicone / Fluorine Oil |
|
Protection Class |
IP65 (Standard) Intrinsically Safe EEx ia IIC T5 (Standard) Explosion proof Ex D IIB T5 |
|
Display |
5 Digits programmable & 0-100% Bargraph |
|
Display Unit |
Standard 22 different engineering unit 5 Digits programmable for special unit |
|
Keypad |
3 internal keys for programming and output setting |
|
Current Output |
4 - 20 mA 2 wires with Hart signal (Compatible) Load : Rohm=(Vdc-9)*50 |
|
Power Supply |
9 - 32 VDC |
|
Damping |
0 - 32 seconds |
|
Response Time |
200 mS |
|
Mounting |
Bracket on 2" Pipe |
|
Humidity Limit |
0 to 100% Relative Humidity |
|
Turn on Time |
2 Seconds with minimum damping |
|
Zero Calibration |
Automatic zero calibration by press-button |
|
Cable Entry |
M20 Conduit Threads / 1/2" NPT (Female) |
|
Temperature Effect |
+/-0.18% ~ +/-0.5% of span per 20 °C |
|
Vibration Effect |
+/-0.05% of URL per g to 200 Hz in any axis |
|
EMI/RFI Effect |
Follow SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m |
|
Process Connection |
2", 3",4",6" Flange
|
|
Ambient Temperature |
-25 to +80 °C |
WIRING DIAGRAM

Dimensions

Order Code:
|
Item |
Code |
Specification |
|
HY3051SDP |
Differential Pressure Transmitter |
|
|
HY3051SGP |
Gauge Pressure Transmitter |
|
|
Measurement Range |
2 |
0-0.1~1.5 Kpa |
|
3 |
0~7.5 Kpa |
|
|
4 |
0~37.4 Kpa |
|
|
5 |
0~186.8 Kpa |
|
|
6 |
0~690 Kpa |
|
|
7 |
0~2068 Kpa |
|
|
8 |
0~6890 Kpa |
|
|
9 |
0~20680 Kpa |
|
|
Output |
S |
4-20mA, HART Protocol, Linear output |
|
J |
4-20mA, HART Protocol, Square root output(Range≥5kpa) |
|
|
Diaphragm Material / Fill Fluid |
2 |
Stainless Steel 316L Silicone Oil |
|
3 |
Hastelloy C(range >3Kpa) Silicone Oil |
|
|
A |
Stainless Steel 316L Fluorine oil |
|
|
Drain hole |
B |
Back of process flange or none |
|
U |
Process flange side upper |
|
|
L |
Process flange side lower |
|
|
Wetted O-ring Material |
7 |
Buna-N (NBR) |
|
6 |
Viton (FKM) (Temperature ≥-20℃) |
|
|
5 |
Low Temperature Viton (FKM-GFLT) |
|
|
Process Connection |
H |
1/4'' NPT F |
|
Maximum Pressure Limit |
1 |
14 Mpa( 4Mpa for range 2) |
|
3 |
25 Mpa |
|
|
5 |
32 Mpa |
|
|
Cable Entry |
1 |
M20*1.5 |
|
Mounting Bracket |
B00 |
None |
|
B01 |
Tube-type Curved Bracket (carbon steel) |
|
|
B02 |
Wall mounting bracket (carbon steel) |
|
|
B03 |
Tube-type Flat Bracket (carbon steel) |
|
|
B04 |
Tube-type Curved Bracket (stainless steel) |
|
|
B05 |
Wall mounting bracket (stainless steel) |
|
|
B06 |
Tube-type Flat Bracket (stainless steel) |
|
|
Optional |
d |
Intrinsically safe type, Flameproof (Exd IIC T4~T6) |
|
i |
Intrinsically safe (Exia IIC T4~T6) |
|
|
M3 |
LCD display |
|
|
D1 |
Stainless steel drain valve or screw (2pcs) |
|
|
C1 |
1/2'' NPT female waist flange (2sets) |
|
|
C12 |
1/2'' NPT-M20*1.5-Φ14 pressure pipe (2sets) |
|
|
C2 |
M20*1.5 male thread T joint (2sets) |
|
|
C21 |
M20*1.5 T joint -Φ14 pressure pipe (2sets) |
|
|
K1 |
Degreasing treatment |
|
Hot Tags: 4-20ma double flange differential pressure transmitter for liquid gas, China 4-20ma double flange differential pressure transmitter for liquid gas manufacturers, suppliers, Absolute Pressure Transmitter, Absolute Pressure Transmitter for Gas Or Liquid, 4 20ma Double Flange Differential Pressure Transmitter for Liquid Gas, Direct Mounted Absolute Pressure Transmitter, Digit Absolute Pressure Transmitter, Smart 3051 Absolute Pressure Transmitter