The thermal gas mass flow meter is designed based on the principle of thermal diffusion, which uses the constant temperature difference method to accurately measure the gas. The utility model has the advantages of small volume, high digitization degree, convenient installation and accurate measurement.

Description

The thermal gas mass flow meter is designed based on the principle of thermal diffusion, which uses the constant temperature difference method to accurately measure the gas. The utility model has the advantages of small volume, high digitization degree, convenient installation and accurate measurement.

 

Features:

Thermal gas mass flow meters have the following technical advantages:

►The real mass flow meter does not require temperature and pressure compensation for gas flow measurement, and the measurement is convenient and accurate. A mass flow rate of the gas or a standard volume flow can be obtained.

►Wide range ratio, can measure gas flow rate up to 120Nm / s down to 0.1Nm / s, can be used for gas leak detection.

►The seismic performance is good and the service life is long. The sensor has no moving parts and pressure sensing parts and is immune to the influence of vibration on the measurement accuracy.

►Easy to install and maintain. Non-stop production installation and maintenance can be achieved where field conditions permit. (requires special customization)

►Digital design. The overall digital circuit measurement, accurate measurement and convenient maintenance.

►RS-485 communication enables factory automation and integration.

►Oxygen, nitrogen, hydrogen, chlorine and multi-component gas measurements.

►blast furnace gas, coke oven gas measurement.

►Gas flow measurement of natural gas, liquefied gas, flare gas, etc.

►Primary and secondary air flow measurements of blast furnaces in the power plant.

►Flow measurement of downhole ventilation or exhaust system in Yanzhou Mine.

►Flue gas measurement.

►Compressed air measurement.

 

Technical performance

performance

Technical Parameters

structure type

Plug-in

Pipeline

Measuring

medium

Common steady-state gases (unstable media such as acetylene and boron trichloride are not measurable)

Pipe diameter range

DN65~4000mm

DN15~2000mm

Flow rate range

0.1~120Nm/s

Accuracy

±1~2.5%

Operating

temperature

sensor:-40~+450℃ converter:-20~+45℃

Working

pressure

Medium pressure≤4.0MPa(≥4.0MPa

Agreement supply)

Medium pressure≤1.6MPa(≥4.0MPa

Agreement supply)

Power supply

(DC 24V )>=12W

Responding speed

1s

Output signal

4-20mA(1500V Optical isolation,Maximum load500ohm),RS-485(1500V Optical isolation)

Call the police

1-2 normally open contacts

Type of supply

Integrated structure

Pipe material

Carbon steel, stainless steel, plastic, etc.

Live display

Four-line LCD display

Display content

Mass flow rate, standard volume flow rate, cumulative flow rate, standard flow rate, etc.

Protection level

IP65,IP67,IP68

Sensor material

stainless steel

Stainless steel, carbon steel

 

Pipe and plug-in structure dimensions

Flange mounting size

Unit:mm

product-645-290

GB/T9119-2000 PN1.6Mpa(16bar) Flat, protruding panel flat welded steel pipe flange

Nominal

diameter

Flange outer

diameter

Center hole

diameter

Screw

hole

Thread

specification

Flange

thickness

Instrument

installation length

DN

D

K

n*L

 

C

L

15

95

65

4*14

M12

12

160

20

105

75

4*14

M12

14

160

25

115

85

4*14

M12

14

160

32

140

100

4*18

M16

16

160

40

150

110

4*18

M16

16

180

50

165

125

4*18

M16

18

180

65

185

145

4*18

M16

20

180

80

200

160

8*18

M16

20

180

100

220

180

8*18

M16

20

200

125

250

210

8*18

M16

20

200

150

285

240

8*22

M20

22

200

200

340

295

12*22

M20

22

200

250

405

355

12*26

M24

24

200

300

460

410

12*26

M24

24

200

 

Wafer mounting dimensions

Unit:mm

product-455-660

Figure 3

Caliber

DN

B

C (CH)

A

15-25

55

390(455)

70

32

55

390(455)

70

40

80

385(440)

85

50

90

390(450)

85

65

105

400(470)

85

80

120

420(480)

85

100

140

440(500)

85

125

165

465(530)

90

150

194

490(560)

100

200

248

545(610)

102

250

300

595(650)

115

300

350

645(710)

130

 

 

 

 

(1)For DN15 ~ DN80 can be usedpipe thread connection.

(2)Only the maximum rated pressure data of 1.6Mpa is given in the table, and it can be customized above the rated pressure.

(3)The integral full tube can be flanged, threaded and snap-fit.

 

Plug-in mounting size

Unit:mm

product-324-584

Figure 4

(1)The integral plug-in type should be inserted into the axis of the pipe to be tested, so the length of the measuring rod depends on the diameter of the measuring pipe. It should be stated when ordering.

(2)If it cannot be inserted into the pipe axis, the factory will provide the calibration factor to complete the accurate measurement.

 

Flow Range

Thermal gas mass flow meter range table

caliber

Base range (air)

(Nm3/h)

Extended range (air)

(Nm3/h)

Oxygen base range

(Nm3/h)

Combustible gas range(Nm3/h)

10

0.5-28

0.03-30

0.5-14

0.5-5

15

0.5-65

0.07-65

0.5-32

0.5-10

20

0.5-100

0.12-110

0.5-55

0.5-20

25

0.5-175

0.18-180

0.5-89

0.5-28

32

0.5-290

0.3-290

0.5-144

0.5-45

40

0.5-450

0.5-450

0.5-226

0.5-70

50

1-600

0.5-700

0.7-352

0.7-110

65

1.5-1000

1-1200

1.2-600

1.2-185

80

2-1500

1.5-1800

2-900

2-280

100

3-2300

3-2800

3-1420

3-470

125

4.5-3500

4-4400

4.5-2210

4.5-700

150

6.5-5200

6-6300

6.5-3200

6.5-940

200

12-9000

12-11500

12-5650

12-1880

250

18-14500

18-17500

18-8830

18-2820

300

25-21000

25-25000

25-12720

25-4060

350

35-28000

35-34500

35-17000

35-5600

400

45-36500

45-45000

45-22600

45-7200

450

60-46500

60-57000

60-29000

60-9200

500

70-57000

70-70000

70-35300

70-11280

600

100-81000

100-101000

100-50600

100-16300

700

140-110000

140-138000

140-69000

140-22100

800

180-150000

180-180000

180-90000

180-29000

900

230-185000

230-230000

230-115000

230-36500

1000

290-230000

290-280000

290-140000

290-45500

2000

1150-900000

1150-1130000

1150-560000

1150-185000

 